Intake door will pivot on a concealed 1/2″ steel pivot shaft to prevent build-up of debris. Intake doors furnished with removable stainless steel door trim with embossed letters (RUBBISH)
Discharge: Type “A” normally open, inclined rolling door with fusible link.
Discharge door panel fabricated to “B” label construction (1″ Thick insulation) even if UL Label is not required.
Vent: Provide full diameter vent 4′-0″ above roof with metal explosion cap.
Floor Frames: Fabricate floor frame 1-1/2″ x 1-1/2″ x 3/16″ angle and 1-1/2″ x 3/16 bar stock welded assembly.
Sprinklers: 1/2 NPT 165-degree sprinkler head with shield above top intake.
Additional 1/2″ Sprinklers and shields at every second intake (or as required by code) 1/2″ NPT Flushing spray head centered in chute above top intake ready for connection by plumber.
Chute Cleaning
A disinfecting and Sanitizing (D&S) unit equipped with adjusting screw to regulate the strength of disinfectant introduced into the flushing water, connected to flushing head spray head.
On-Off valve on unit permits ability to bypass disinfecting units require 15″ x 15″ high side hinged stainless steel access doo bearing UL “B” Label
One Year Warranty
Overview:
C-Tec’s Trash and Recycling Chutes for commercial and industrial use are the most convenient, simple and low-cost method of controlling the disposal of refuse, in mid or high rise residential or commercial buildings. C-Tec’s Trash/Recycling Chutes are fitted internally or externally in new buildings or as replacement Trash Chutes in existing buildings.